Welcome to Carver Yachts Owners Forum

We are a boating forum for owners of Carver Yachts to enthusiastically discuss all aspects of Carver Boat ownership. Whether you are looking for your first Carver or currently own one, you are sure to feel at home on CarverYachtOwners.com

You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!

A/C compressor issue

Discussion of AC's, plumbing and sanitation related issues.
User avatar

Topic author United States of America
ColRon
Admiral
Admiral
Posts: 581
Joined: April 24th, 2017, 6:06 pm
Vessel Info: 1989 Carver Santego 3867
“Escape Plan”
Location: Murray, KY
Has thanked: 77 times
Been thanked: 157 times

A/C compressor issue

Postby ColRon » November 18th, 2025, 12:44 pm

I have a Dometic Cruisair STQ16 A/C in My Salon. The other day, it was in cool mode and quit normal operation. I found it was showing 98 degrees on the Thermostat, the water pump and fan were running and water was flowing, but the compressor was not running and it was not cooling. the actual inside temp was around 55 degrees. I turned the unit off. I turned the unit off and then turned it on to the Auto mode. The heat cycle kicked on and everything operated normally and it began heating the salon to the set temp of 70 degrees. The following day, the unit kick off again and the compressor was not running, but the fan and water pump were running.

What I have found... When i turn the unit on everything seems to work as normal, the fan comes on, I then hear a click and the water pump starts and then I hear a click for the compressor, however the compressor does not start. Water flow is good, and there is no air handler blockage. I have ran both a low and high pressure switch test at the controller and both report ok and no errors. From what I understand, it the unit is low on freon, I should get an error from the low pressure switch. I also did a system reset at the controller, but no change in condition.

It problem appears to be related to the compressor, does anyone have an ideas on what to look for next?
Ron
1989 Carver Santego 3867
“Escape Plan”
Murray, KY

:usa:

User avatar

United States of America
km1125
Admiral
Admiral
Posts: 3626
Joined: February 28th, 2017, 6:04 pm
Has thanked: 78 times
Been thanked: 1093 times

Re: A/C compressor issue

Postby km1125 » November 18th, 2025, 4:23 pm

Not sure on that specific model, but a lot of the compressors have a breaker mounted on the top of them that will protect against hi temperatures on the compressor or high current draw. Normally they would reset on their own, but it could be defective. They're called Klixon and you can do an online search to see what you'd be looking for.

But also clarify one thing in your OP... in the first paragraph, it sounds like when you reset it then it will run OK for some time and then stop working, but the second paragraph is sounds like it's not working at all now.

Return to “AC/Heat, Plumbing & Sanitation”



Who is online