You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!
Head over filling bowl when water pump on - HELP
- gperkins007
- Scurvy Dog
- Posts: 8
- Joined: August 24th, 2022, 6:25 pm
- Vessel Info: 1988 Carver 32 convertible
- Been thanked: 1 time
Head over filling bowl when water pump on - HELP
Just bought a 1988 Carver 32 3227.
When I turn on the main water pump the toilet fills up and then overflows continuously.
Been reading this could be a stuck solonoid?
Some pictures if anyone can help me identify my model head and if that blue pump thing is in fact the solonoid.
It does tap off the main water line and goes to the top of the bowl.
Should that only enable water flow while the flush button is being pushed?
thank you!
Gary
- gperkins007
- Scurvy Dog
- Posts: 8
- Joined: August 24th, 2022, 6:25 pm
- Vessel Info: 1988 Carver 32 convertible
- Been thanked: 1 time
Re: Head over filling bowl when water pump on - HELP
I assume that when the pump is not running it should not be allowing water to come in from the the main fresh water line.
And in my case it is?
- km1125
- Admiral
- Posts: 3342
- Joined: February 28th, 2017, 6:04 pm
- Has thanked: 57 times
- Been thanked: 968 times
Re: Head over filling bowl when water pump on - HELP
You might just have some dirt in the solenoid valve. You might be able to disconnect it and hook the hoses up "backwards" for a minute to see if that would flush the debris out, or you can disassemble it and see if it's clean. With the water pressure off, when you flush you should hear a good "click" in that solenoid valve.
You might not be able to flush it backwards if that backflow prevention valve is still in place. You may have to remove that to do the backflush.
- gperkins007
- Scurvy Dog
- Posts: 8
- Joined: August 24th, 2022, 6:25 pm
- Vessel Info: 1988 Carver 32 convertible
- Been thanked: 1 time
Re: Head over filling bowl when water pump on - HELP
- bud37
- Admiral
- Posts: 4677
- Joined: April 23rd, 2015, 10:22 pm
- Has thanked: 547 times
- Been thanked: 1143 times
Re: Head over filling bowl when water pump on - HELP
gperkins007 wrote:Source of the post Thank you very much!! Will try this out and report...looks like will be a bear to access all this. Located under sink where the two drawers are.
Also check for power at the valve when the switch is activated and if there is power, tap the valve with a screwdriver handle and see if loosens up......good luck.
- gperkins007
- Scurvy Dog
- Posts: 8
- Joined: August 24th, 2022, 6:25 pm
- Vessel Info: 1988 Carver 32 convertible
- Been thanked: 1 time
Re: Head over filling bowl when water pump on - HELP
- gperkins007
- Scurvy Dog
- Posts: 8
- Joined: August 24th, 2022, 6:25 pm
- Vessel Info: 1988 Carver 32 convertible
- Been thanked: 1 time
Re: Head over filling bowl when water pump on - HELP
- km1125
- Admiral
- Posts: 3342
- Joined: February 28th, 2017, 6:04 pm
- Has thanked: 57 times
- Been thanked: 968 times
Re: Head over filling bowl when water pump on - HELP
gperkins007 wrote:Source of the post and so to be clear please, this is NOT a pump, just a solenoid switch and problem could be its stuck open?
Correct.
You could also put a manual valve in that line so you could shut the feed off if the solenoid valve ever leaks again, to prevent an overflow and give you time to work on the valve. If you installed it BEFORE the solenoid valve, then you could also leave the rest of the potable system running while you shut the valve off to work on the solenoid valve.
-
- CYO Supporter
- Posts: 5803
- Joined: July 10th, 2015, 9:58 pm
- Vessel Info: 1989 Carver 3807 Aft Cabin
- Location: Ontario, Canada
- Has thanked: 431 times
- Been thanked: 1586 times
Re: Head over filling bowl when water pump on - HELP
Looks like you have a Raritan Crown head set up for fresh water flush but your plumbing setup is not factory.
- gperkins007
- Scurvy Dog
- Posts: 8
- Joined: August 24th, 2022, 6:25 pm
- Vessel Info: 1988 Carver 32 convertible
- Been thanked: 1 time
Re: Head over filling bowl when water pump on - HELP