You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!

Dead Engines - No ignition

Discussion of batteries, chargers, wiring, generators, distribution panels, battery switches, etc.
User avatar

Topic author
Maluhia
Scurvy Dog
Scurvy Dog
Posts: 3
Joined: May 1st, 2015, 4:40 pm
Vessel Info: 92 Carver 534

Dead Engines - No ignition

Postby Maluhia » May 26th, 2015, 8:38 pm

I have a 92 Carver 534 with twin 7.4L Mercruisers. We recently had a new inverter installed and the electrician noted numerous problems with the boats electrical system that we agreed to have repaired. We replaced 4 batteries, replaced battery breaker switches, installed ACR's and rewired the main electrical panel. Before this was done the boat ran fine, we just didn't have a split bank and no way to operate 110v equipment when we were off shore power and the boat does not have an installed genset. After all this work was done, the next time we used the boat it started fine and took us to our destination, but would do nothing when it was time to pull anchor and go home. Neither ignition worked for either engine. No click, nothing. Batteries were fine. Boat was towed back to the home marina and the electrician could find nothing wrong. We checked all breakers we could find and found nothing wrong. Ignition fuses were changed. Still nothing. The starter circuit isn't that complicated and it has to be a problem that effects both engines. Any ideas?
Maluhia
92 Carver 534

User avatar

Canada
Lyndon670
Admiral
Admiral
Posts: 657
Joined: July 29th, 2013, 11:35 pm
Vessel Info: 2000 Carver 506
Volvo TAMD74EDC
Location: Georgian Bay
Has thanked: 124 times
Been thanked: 138 times

Re: Dead Engines - No ignition

Postby Lyndon670 » May 26th, 2015, 10:25 pm

Too many things to look at. Did you try running power directly to the starter(s)? Start working bacwords from there. Could be something as simple as a bad ground...
Lyndon,
2000 Carver 506
FOXY JOE
Volvo 7.4TAMD
Queens Cove Marina
Georgian Bay, Ontario
User avatar

United States of America
waybomb
CYO Moderator
CYO Moderator
Posts: 2404
Joined: February 5th, 2013, 9:24 pm
Vessel Info: 1995 Boston Whaler Rage15
1987 3697 Carver Mariner
1988 Cougar 46 Kevlar Vee offshore
1969 15' Glasspar / 1967 Johnson Electromatic 85
1996 Boston Whaler Rage 15
Location: Saint Joseph,Mi
Has thanked: 50 times
Been thanked: 396 times

Re: Dead Engines - No ignition

Postby waybomb » May 27th, 2015, 11:57 am

Crazy things happen - are both neutral safety switches good?
As Lyndon says - are the ground shared? Could simply be a loose nut.
Thanks
Fred
1969 Glaspar Avalon /1969 Johnson Electromatic 85
1987 Carver Mariner
1988 Cougar Kevlar 46' with triple blown 572 ci
1995 Boston Whaler Rage
Past - 1988 2807, 1989 4207 Aft
User avatar

Topic author
Maluhia
Scurvy Dog
Scurvy Dog
Posts: 3
Joined: May 1st, 2015, 4:40 pm
Vessel Info: 92 Carver 534

Re: Dead Engines - No ignition

Postby Maluhia » May 27th, 2015, 7:51 pm

Lyndon670 and waybomb,
Thanks for your input. That is what I was thinking. Most likely it will be something simple that is common to both starters and ignition switches.
User avatar

Nplbw
Scurvy Dog
Scurvy Dog
Posts: 4
Joined: July 6th, 2013, 11:12 am
Vessel Info: 2005 Carver 411 CMY Volvo penta d6 370 hp

Re: Dead Engines - No ignition

Postby Nplbw » August 11th, 2015, 8:35 pm

Were you able to determine what the problem was and fix it?