You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!

Generator smoke from exhaust

Discussion of batteries, chargers, wiring, generators, distribution panels, battery switches, etc.
User avatar

Topic author Canada
Gilligan 1955
Scurvy Dog
Scurvy Dog
Posts: 11
Joined: June 9th, 2024, 9:11 am
Vessel Info: 1989 Carver 3807
Location: Peterborough
Has thanked: 9 times

Generator smoke from exhaust

Postby Gilligan 1955 » July 2nd, 2024, 2:34 pm

Only owned a 3807 1989 for a week. Started generator and had smoke coming out of exhaust then it shut down after less than 2 mins. I think I've sucked up weeds and it over heated. Has no "sea strainer" or sea cock to shut off water intake. Can I remove the water intake hose from the inner cooler at the generator to check for weeds? As long as I keep the hose end above the water line? Or will I sink? New to this group and I'm already in trouble. Thanks

User avatar

United States of America
waybomb
CYO Moderator
CYO Moderator
Posts: 2686
Joined: February 5th, 2013, 9:24 pm
Vessel Info: 1995 Boston Whaler Rage15
1987 3697 Carver Mariner
1988 Cougar 46 Kevlar Vee offshore
1969 15' Glasspar / 1967 Johnson Electromatic 85
Location: Saint Joseph,Mi
Has thanked: 64 times
Been thanked: 481 times

Re: Generator smoke from exhaust

Postby waybomb » July 2nd, 2024, 3:55 pm

Your not going to sink the boat if you I open a line for a little while. I can't believe theres no seacock! That's dangerous. I think you may be overlooking it. It has to be there.
Thanks
Fred
1969 Glaspar Avalon /1967 Johnson Electromatic 85
1987 Carver Mariner
1988 Cougar Kevlar 46' with triple blown 572 ci
1995 Boston Whaler Rage
Past - 1988 2807, 1989 4207 Aft
User avatar

United States of America
km1125
Admiral
Admiral
Posts: 3624
Joined: February 28th, 2017, 6:04 pm
Has thanked: 78 times
Been thanked: 1093 times

Re: Generator smoke from exhaust

Postby km1125 » July 2nd, 2024, 4:30 pm

I agree.. there absolutely should be a seacock on the incoming water line.

Earlier freshwater models didn't usually come with strainers for the engines or genset. The owner had to add those if they wanted them, so I wouldn't be surprised that you don't have one. But they are a good idea to have.

Do you know that it has a good impeller in it?

What exact model genset is it? You'll get a lot better responses if folk know that.
User avatar

Topic author Canada
Gilligan 1955
Scurvy Dog
Scurvy Dog
Posts: 11
Joined: June 9th, 2024, 9:11 am
Vessel Info: 1989 Carver 3807
Location: Peterborough
Has thanked: 9 times

Re: Generator smoke from exhaust

Postby Gilligan 1955 » July 2nd, 2024, 5:32 pm

It's a Kohler generator. The intake water line goes straight from the through hull to the inner cooler. Adding a sea cock will be a project for when it comes out in the Fall. I'm also concerned that there may not be sea cocks for the engines either. If the connection is above the water line at the generator can it be safely removed? Would it be like a syphon where the source needs to be higher to flow.
User avatar

Canada
bud37
Admiral
Admiral
Posts: 5122
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 598 times
Been thanked: 1281 times

Re: Generator smoke from exhaust

Postby bud37 » July 2nd, 2024, 8:26 pm

Gilligan 1955 wrote:Source of the post It's a Kohler generator. The intake water line goes straight from the through hull to the inner cooler. Adding a sea cock will be a project for when it comes out in the Fall. I'm also concerned that there may not be sea cocks for the engines either. If the connection is above the water line at the generator can it be safely removed? Would it be like a syphon where the source needs to be higher to flow.



Could you post a pic of the hose where it comes from this thru hull you are referencing. FWIW it is quite easy to install a shut off valve in the inlet hose between the hull and the cooler if that is something you need to do.
FWIW.....The above is just my opinion.

Canada
Viper
CYO Supporter
CYO Supporter
Posts: 6209
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 469 times
Been thanked: 1765 times

Re: Generator smoke from exhaust

Postby Viper » July 2nd, 2024, 9:22 pm

Is the intake hose hooked up to a thru-hull behind the port engine? If there is no valve, it must have failed and a previous owner opted to remove and not replace it. It would not come from factory without a seacock.

Do you have a Kohler 7.5A/R? What do you mean by "inner cooler"? If it's like mine, the intake hose should go to the water pump first.

You can remove the intake hose at the water pump as long as it's mounted up high. It would be if you have the model I mentioned above.

If your 3807 is like mine with the exhaust holes out the sides, you'll see exhaust but the water usually comes out of the holes underneath, not the side holes, and because they are so close to the water, it can be difficult to tell whether it's pumping water or not. You can feel the exhaust hose or the elbow, it should not be very hot if she's pumping water.
User avatar

United States of America
waybomb
CYO Moderator
CYO Moderator
Posts: 2686
Joined: February 5th, 2013, 9:24 pm
Vessel Info: 1995 Boston Whaler Rage15
1987 3697 Carver Mariner
1988 Cougar 46 Kevlar Vee offshore
1969 15' Glasspar / 1967 Johnson Electromatic 85
Location: Saint Joseph,Mi
Has thanked: 64 times
Been thanked: 481 times

Re: Generator smoke from exhaust

Postby waybomb » July 3rd, 2024, 9:48 am

I am also surprised insurance would cover you with a policy. This should have been indicated on the survey.
I'd be pulling the boat now and installing seacocks.
Thanks
Fred
1969 Glaspar Avalon /1967 Johnson Electromatic 85
1987 Carver Mariner
1988 Cougar Kevlar 46' with triple blown 572 ci
1995 Boston Whaler Rage
Past - 1988 2807, 1989 4207 Aft