You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!

Kohler Generator Voltage Irregularity

Discussion of batteries, chargers, wiring, generators, distribution panels, battery switches, etc.
User avatar

Topic author United States of America
tim.lesage@twc.com
Scurvy Dog
Scurvy Dog
Posts: 4
Joined: March 1st, 2025, 5:26 pm
Vessel Info: 2001 Carver 570 Voyager
Location: Racine, WI

Kohler Generator Voltage Irregularity

Postby tim.lesage@twc.com » July 13th, 2025, 9:57 am

I recently purchased a 2002 Carver 570 Voyager. It has a Kohler 15.5 EOZ generator. When the boat was surveyed the surveyor noted the voltage needle to have some irregularity when it starts up, with voltage fluctuating between 220 and 280 V. The engine sounds quite regular during this time, and once the generator realizes its load it settles out at a constant voltage (takes less than a minute). The surveyor recommended having a generator specialist evaluate, which we did and they recommended some work including replacing belts and diodes on voltage regulator. $4000 later it still does same thing, and they now think it is insulation on the windings, which would be very expensive to deal with. The seller of the boat then sent out his own mechanic to evaluate (not sure of his true qualifications). His mechanic evaluated and replaced impeller and stated generator is working fine. He said voltage fluctuation is normal when generator is seeking out its load. i had another Kohler certified generator service evaluate after that to verify, but they said this degree of voltage fluctuation is beyond what would normally be expected. The sellers mechanic also mentioned that trusting the voltage needle that is on the panel may not be possible as it is a low quality indicator. Looking for advice/opinions on where to go from here. Money was escrowed upon closing to deal with things like this, but seller believes generator needs no more work since his mechanic stated it is fine. I have video showing the voltage needle during this period that I am happy to share with anybody that wants to see if. My dilemma is that I have had two separate Kohler certified service technicians say there is a problem, and one mechanic send by seller (who did seem quite knowledgable, but of unknown qualification) who says it is fine. I very badly want it to be fine so we can move on, but I believe it may not be. Relationship between me and seller/broker has unfortunately become a bit contentious. Any advice here would be greatly appreciated.

User avatar

Canada
bud37
Admiral
Admiral
Posts: 5118
Joined: April 23rd, 2015, 10:22 pm
Has thanked: 597 times
Been thanked: 1281 times

Re: Kohler Generator Voltage Irregularity

Postby bud37 » July 13th, 2025, 10:32 am

Sorry I can't say with any certainty , but I do understand engine speed governors....have any of them just checked the governor control on start up, if it is a spring type is may just be getting weak. Anyhow maybe a question to put forward as engine rpm control is necessary for stable operation of those things.
FWIW.....The above is just my opinion.
User avatar

United States of America
km1125
Admiral
Admiral
Posts: 3619
Joined: February 28th, 2017, 6:04 pm
Has thanked: 76 times
Been thanked: 1090 times

Re: Kohler Generator Voltage Irregularity

Postby km1125 » July 13th, 2025, 7:13 pm

tim.lesage@twc.com wrote:Source of the post... $4000 later it still does same thing...

YIKES!! That would piss me off if they did that much work and really had no clue that it would or wouldn't solve the problem!!

tim.lesage@twc.com wrote:Source of the post
... and they now think it is insulation on the windings, which would be very expensive to deal with. ...

I cannot fathom a failure mode on the windings that would cause that kind of an issue.


bud37 wrote:Sorry I can't say with any certainty , but I do understand engine speed governors....have any of them just checked the governor control on start up, if it is a spring type is may just be getting weak. Anyhow maybe a question to put forward as engine rpm control is necessary for stable operation of those things.

There is at least one model of genset (I can't recall which) that uses an oil-filled governor. That oil is supposed to be changed periodically and if it's not then the governor is slow to react and will not compensate properly.
User avatar

United States of America
ck36
Scurvy Dog
Scurvy Dog
Posts: 23
Joined: May 10th, 2025, 11:23 am
Vessel Info: 2002 Carver 450 Voyager, TAMD74P
Location: Washington
Has thanked: 13 times

Re: Kohler Generator Voltage Irregularity

Postby ck36 » July 14th, 2025, 11:05 am

He said voltage fluctuation is normal when generator is seeking out its load.

I assume you’re seeing this behavior when starting the generator under no load?

The sellers mechanic also mentioned that trusting the voltage needle that is on the panel may not be possible as it is a low quality indicator.

Perhaps, but if it’s behaving consistently, it’s probably still an accurate indicator. For $4000 I would think the previous mechanics would have verified that the voltmeter was working correctly?
User avatar

Topic author United States of America
tim.lesage@twc.com
Scurvy Dog
Scurvy Dog
Posts: 4
Joined: March 1st, 2025, 5:26 pm
Vessel Info: 2001 Carver 570 Voyager
Location: Racine, WI

Re: Kohler Generator Voltage Irregularity

Postby tim.lesage@twc.com » July 14th, 2025, 2:00 pm

Yes, this behavior is noted when the generator first starts up, once AC devices (especially higher load ones like
HVAC) kick in if settles out and no longer fluctuates. It even
stays constant af that point if I turn off the load. I ordered a new voltage meter myself to try that out - should
have that by the end of the week.