You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!

(1988) Kohler 7.5KW Generator

GAS engine, transmission and generator repair and maintenance discussion forum.
User avatar

Topic author
Ondercin
Scurvy Dog
Scurvy Dog
Posts: 20
Joined: April 20th, 2015, 5:48 pm
Vessel Info: 1988 carver 3607 AFT
Penetanguishene
Has thanked: 2 times
Been thanked: 3 times

(1988) Kohler 7.5KW Generator

Postby Ondercin » June 13th, 2016, 1:56 pm

I'm trying to locate valve springs for our Kohler generator, I believe its the original in our 1988 Carver 3607

The genny runs fine on loads of 15amps or less, but anything higher causes the engine to run hard and shutdown.
1988 carver 3607 AFT
Penetanguishene

User avatar

United States of America
g36
Admiral
Admiral
Posts: 2087
Joined: April 7th, 2014, 6:07 pm
Vessel Info: 1997 Carver 405
Location: Soddy Daisy TN.
Has thanked: 7 times
Been thanked: 641 times

Re: (1988) Kohler 7.5KW Generator

Postby g36 » June 13th, 2016, 2:45 pm

Why would jump to valve springs being the cause.have you checked or adjusted them? or compression low etc? Just wondering how you made the jump to the springs?
How about checking temp with the larger load compared to the no load, good water flow or another sensor shutting down the unit.
Last edited by g36 on June 13th, 2016, 2:52 pm, edited 1 time in total.
1997 Carver 405
Crusader xli
The Black Pearl
Soddy Daisy Tn.
User avatar

Topic author
Ondercin
Scurvy Dog
Scurvy Dog
Posts: 20
Joined: April 20th, 2015, 5:48 pm
Vessel Info: 1988 carver 3607 AFT
Penetanguishene
Has thanked: 2 times
Been thanked: 3 times

Re: (1988) Kohler 7.5KW Generator

Postby Ondercin » June 13th, 2016, 2:52 pm

Just guessing... When the engine starts to rev higher, it's either starving for fuel or just a guess that one of the valve springs are broken... Just going to pop the cover off now to inspect the valves.
I've replaced the fuel pump with a new electric pump, and the fuel is flowing.
1988 carver 3607 AFT
Penetanguishene
User avatar

Livinthedream
Scurvy Dog
Scurvy Dog
Posts: 3
Joined: May 28th, 2016, 9:25 am
Location: Sudbury
Been thanked: 1 time

Re: (1988) Kohler 7.5KW Generator

Postby Livinthedream » June 13th, 2016, 4:00 pm

I would clean the carb. Most likely leaning out inter load. Or possibly overheating under a big load.

Canada
Viper
CYO Supporter
CYO Supporter
Posts: 6187
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 467 times
Been thanked: 1759 times

Re: (1988) Kohler 7.5KW Generator

Postby Viper » June 13th, 2016, 7:51 pm

Ya could be a number of things. Check the simple stuff first with proper diagnostics before you get into internal engine components.
User avatar

Topic author
Ondercin
Scurvy Dog
Scurvy Dog
Posts: 20
Joined: April 20th, 2015, 5:48 pm
Vessel Info: 1988 carver 3607 AFT
Penetanguishene
Has thanked: 2 times
Been thanked: 3 times

Re: (1988) Kohler 7.5KW Generator

Postby Ondercin » June 16th, 2016, 9:12 am

So it appears the distributor was off by 1, so the timing was out...
Now the genny runs great, the only thing left to figure out is it's overheating a bit after 3 or so hours and not shutdown down automatically.
1988 carver 3607 AFT
Penetanguishene

Canada
Viper
CYO Supporter
CYO Supporter
Posts: 6187
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 467 times
Been thanked: 1759 times

Re: (1988) Kohler 7.5KW Generator

Postby Viper » June 16th, 2016, 9:13 pm

Ondercin wrote:Source of the post ....it's overheating a bit after 3 or so hours and not shutdown down automatically.

Are you saying that it is overheating but not shutting down automatically? If so, you have a faulty overtemp switch. Or do you mean it does shut down automatically?

What do you mean by "a bit" and how are you coming to the conclusion that it is overheating?

There are several things that will cause an overheat; t-stat, restricted raw water flow, faulty pump/impeller, air in system, clogged raw water circuit, timing, bad heat exchanger, bad coolant, low coolant....etc.
User avatar

Topic author
Ondercin
Scurvy Dog
Scurvy Dog
Posts: 20
Joined: April 20th, 2015, 5:48 pm
Vessel Info: 1988 carver 3607 AFT
Penetanguishene
Has thanked: 2 times
Been thanked: 3 times

Re: (1988) Kohler 7.5KW Generator

Postby Ondercin » June 16th, 2016, 11:10 pm

It's not shutting down, after about 3 hours the temp is sitting around 160.. I have good water flow coming out the exhaust. I checked the impeller (twice) and it's perfect!
I am guessing the overtemp switch, but I haven't been able to test it yet... Perhaps on Saturday over a few beers!
1988 carver 3607 AFT
Penetanguishene

Canada
Viper
CYO Supporter
CYO Supporter
Posts: 6187
Joined: July 10th, 2015, 9:58 pm
Vessel Info: 1989 Carver 3807 Aft Cabin
Location: Ontario, Canada
Has thanked: 467 times
Been thanked: 1759 times

Re: (1988) Kohler 7.5KW Generator

Postby Viper » June 17th, 2016, 7:34 am

I'll have to check specs but I don't think 160 is an issue. It's normal temp for closed cooling main engines, I just don't recall what the spec is for this generator. Pretty sure the over-temp switch doesn't activates at about 200. Again, I'll have to check. If you have the manual, it'll be in there.